Media Center Automation: Difference between revisions

From wiki.jriver.com
Jump to navigation Jump to search
No edit summary
 
(8 intermediate revisions by 4 users not shown)
Line 47: Line 47:
* [[MJPlaylistsAutomation]] - represents a collection of playlists
* [[MJPlaylistsAutomation]] - represents a collection of playlists
* [[MJPlaylistAutomation]] - interface for working with a single playlist
* [[MJPlaylistAutomation]] - interface for working with a single playlist
* [[MJSchemeAutomation]] - interface for working with Media Library
* [[MJSchemeAutomation]] - interface for working with Media Library View Schemes
* [[MJVersionAutomation]] - interface for getting Media Center version information
* [[MJVersionAutomation]] - interface for getting Media Center version information
* [[MJInternetAutomation]] - interface for helping in downloading files from internet
* [[MJInternetAutomation]] - interface for helping in downloading files from internet
Line 109: Line 109:
** Fired when the volume is changed
** Fired when the volume is changed
** ''string3'' is the zone
** ''string3'' is the zone
* '''MCC: NOTIFY_EQ_CHANGED'''
** MCC 12.0.217 or higher
** Fired when the Equalizer settings are changed, or the Equalizer is turned on or off.
** ''string3'' is not used
** Because of internal implementation considerations, you will receive multiple copies of this event for each trigger.


===Event Handling and Zones===
===Event Handling and Zones===
Line 118: Line 123:
1. Add a reference to Media Center's type library ("Media Center 12.tlb"). In VB.NET use the Projects/Add Reference option, select the "COM" tab, then select "MediaCenter" from the list.
1. Add a reference to Media Center's type library ("Media Center 12.tlb"). In VB.NET use the Projects/Add Reference option, select the "COM" tab, then select "MediaCenter" from the list.


2. Add the "Imports MediaCenter" statement to your code.
2. Add the "Imports MediaCenter" statement to declaration section of the code.


3. In the main class section for your project (e.g. - Form1) do the following:
3. Declare your MC automation variable to handle events, like this:
A) Declare your MC automation variable to handle events, like this:
Dim WithEvents MC As MCAutomation
Dim WithEvents MC As MediaCenter.MCAutomation


B) Create a delagate class object and set it up to handle the three parameters passed by MEDIACENTER's object:
4. Set the MC variable using either GetObject or CreateObject as described elsewhere in this document.
Private _RelayEvent As RelayEvent
Delegate Sub RelayEvent(ByVal EventData1 As String, ByVal EventData2 As String, ByVal EventData3 As String)


4. Create a subroutine to receive the event message and to perform actions based on it. It is triggered by the event handler created below in step 4:
5. Declare a handler function for the event like this:
Private Sub MJEvent(ByVal s1 As String, ByVal s2 As String, ByVal s3 As String) Handles MC.FireMJEvent
Private Sub MyRelayEvent(ByVal EventData1 As String, ByVal EventData2 As String, ByVal EventData3 As String)
lbParam1.Text = EventData1
MsgBox(s1 + " " + s2)
lbParam2.Text = Trim(EventData2)
End Sub
lbParam3.Text = EventData3
Application.DoEvents()
End Sub


4. Declare a handler function for the event. In the handler function, your will need to assign the delegate pointer to the subroutine that will actually act on the event. Then use the BeginInvoke function to transfer the event data when it is received:
6. That's it. Events fired from MediaCenter should come to your function.
Public Sub MC_FireMJEvent(ByVal s0 As String, ByVal s1 As String, ByVal s2 As String) Handles MC.FireMJEvent
_RelayEvent = New RelayEvent(AddressOf MyRelayEvent)
BeginInvoke(_RelayEvent, s0, s1, s2)
End Sub


5. Events fired from MediaCenter will be received by "MC_FireMJEvent" and it will use the delegate pointer to trigger "MyRelayEvent", which can act on the event.

Note: The event handler is automatically created in a separate thread from the main routine/class. One thread cannot make changes to another thread, so it is necessary to use the delegate pointer to make the main thread aware that the event occured and to receive the information. Then the receiving subroutine, which is in the main thread, can make updates without creating an exception error.


===Handling the events from Visual C++ with MFC===
===Handling the events from Visual C++ with MFC===
Line 222: Line 242:


Here's the (somewhat) tricky part. Using the CComComposite class means that AtlAdviseSinkMap is called during the window constructor, and it will cause an ATLASSERT failure during debug builds. This produces the "Abort" "Retry" "Ignore" message box stating there's been an assertion failure in atlcom.h. Click ignore. Once you move to release builds, it will compile to nothing and will not cause you any trouble.
Here's the (somewhat) tricky part. Using the CComComposite class means that AtlAdviseSinkMap is called during the window constructor, and it will cause an ATLASSERT failure during debug builds. This produces the "Abort" "Retry" "Ignore" message box stating there's been an assertion failure in atlcom.h. Click ignore. Once you move to release builds, it will compile to nothing and will not cause you any trouble.

[[Category:Developer]]

Latest revision as of 15:30, 7 April 2014

Media Center exports much of its power and functionality through COM automation interfaces. This makes it easy to create your own plug-ins for Media Center that integrate tightly with its interface. Since automation interfaces are based on COM, these plug-ins can be written in almost any language. (C++, VB, Delphi, etc.). Also, the interfaces can be accessed in Metamorphis skins and Display plug-ins (see documentation for the plug-ins). Prior to build 9.1.238, the only way to access the automation interfaces was to write a plug-in for MC because the interfaces were not accessible by objects which were outside Media Center's process. Now, any application, including VBS and Java script, can start MC or just run it to query information about MC's database.

The functions in this document are for Media Center 11.1. Most will work with earlier versions, but not all.

Initialization

Media Center can be initialized by in-proc or out-of-proc objects.

Out-of-proc initialization (C++):

#import "Media Jukebox.tlb" no_namespace, named_guids

void GetMJAutomation()
{
    IMJAutomationPtr pMJ;

    HRESULT hr = pMJ.GetActiveObject (L"MediaJukebox Application");
    if (hr != S_OK)
        pMJ.CreateInstance(L"MediaJukebox Application");
}

Out-of-proc initialization (VB):

Private Sub Form_Load()
' First try to get an already running object
On Error Resume Next
Set myobj = GetObject(, "MediaJukebox Application")

If Err.Number = 429 Then
    'Then, create a new object
    Set myobj = CreateObject("MediaJukebox Application")

End Sub

NOTE: If Media Center was created as out-of-proc object, the main window of the program will be invisible. To show the window use ShowProgram function from MJAutomation interface.

For information on how to get access to MJAutomation interface from in-proc plug-ins see plug-in SDK.

Automation Objects

Event Handling

MediaCenter version 11.1 and higher supports an event interface for automation clients.

Basics

An event is fired upon certain actions with three string parameters:

FireMJEvent(string1, string2, string3)

The first parameter is the event type and currently there is just one event type, namely "MJEvent type: MCCommand" The second parameter identifies the MCC command. See the list below. The third parameter is optional and may contain information specific to the command.

Here are the commands currently sent to the event handler:

  • MCC: NOTIFY_TRACK_CHANGE
    • Fired when a new track starts to play
    • string3 is the zone
  • MCC: NOTIFY_PLAYERSTATE_CHANGE
    • Fired when a the player state changes
      • A new track starts to play
      • Playback is stopped, paused, or started
    • string3 is the zone
  • MCC: NOTIFY_PLAYLIST_ADDED
    • Fired when a playlist is added by the user
    • string3 is the playlist ID
  • MCC: NOTIFY_PLAYLIST_INFO_CHANGED
    • Fired when a playlist is renamed
    • Fired when a smartlist rule is changed
    • Fired when a station is added to My Stations
    • string3 is the playlist ID
  • MCC: NOTIFY_PLAYLIST_FILES_CHANGED
    • Fired when a playlist's files change
    • Fired when a service notifies Media Center that the service's playlists need to be refreshed
    • string3 is the playlist ID
  • MCC: NOTIFY_PLAYLIST_REMOVED
    • Fired when a playlist is removed
    • string3 is the ID of the deleted playlist
  • MCC: NOTIFY_PLAYLIST_COLLECTION_CHANGED
    • Fired when a playlist is moved or copied
    • string3 is not used
  • MCC: NOTIFY_PLAYLIST_PROPERTIES_CHANGED
    • Fired when a playlist property is changed
    • string3 is the playlist ID
  • MCC: NOTIFY_SKIN_CHANGED
    • MC 12.0.211 or higher
    • Fired when the skin is changed
    • string3 is not used
  • MCC: NOTIFY_VOLUME_CHANGED
    • MC 12.0.217 or higher
    • Fired when the volume is changed
    • string3 is the zone
  • MCC: NOTIFY_EQ_CHANGED
    • MCC 12.0.217 or higher
    • Fired when the Equalizer settings are changed, or the Equalizer is turned on or off.
    • string3 is not used
    • Because of internal implementation considerations, you will receive multiple copies of this event for each trigger.

Event Handling and Zones

The events MCC: NOTIFY_TRACK_CHANGE and MCC: NOTIFY_PLAYERSTATE_CHANGE contain the zone where the change occurred. Media Center, however, will only notify changes in the currently active zone. If a track changes in the non-active zone, there will be no event. Only track changes in the active zone will have events.

Handling the events from Visual Basic

To add a handler in VB.NET for events coming from Media Center:

1. Add a reference to Media Center's type library ("Media Center 12.tlb"). In VB.NET use the Projects/Add Reference option, select the "COM" tab, then select "MediaCenter" from the list.

2. Add the "Imports MediaCenter" statement to declaration section of the code.

3. In the main class section for your project (e.g. - Form1) do the following:

  A) Declare your MC automation variable to handle events, like this:
        Dim WithEvents MC As MediaCenter.MCAutomation
  B) Create a delagate class object and set it up to handle the three parameters passed by MEDIACENTER's object:
        Private _RelayEvent As RelayEvent
        Delegate Sub RelayEvent(ByVal EventData1 As String, ByVal EventData2 As String, ByVal EventData3 As String)

4. Create a subroutine to receive the event message and to perform actions based on it. It is triggered by the event handler created below in step 4:

  Private Sub MyRelayEvent(ByVal EventData1 As String, ByVal EventData2 As String, ByVal EventData3 As String)
     lbParam1.Text = EventData1
     lbParam2.Text = Trim(EventData2)
     lbParam3.Text = EventData3
     Application.DoEvents()
  End Sub

4. Declare a handler function for the event. In the handler function, your will need to assign the delegate pointer to the subroutine that will actually act on the event. Then use the BeginInvoke function to transfer the event data when it is received:

  Public Sub MC_FireMJEvent(ByVal s0 As String, ByVal s1 As String, ByVal s2 As String) Handles MC.FireMJEvent
     _RelayEvent = New RelayEvent(AddressOf MyRelayEvent)
     BeginInvoke(_RelayEvent, s0, s1, s2)
  End Sub


5. Events fired from MediaCenter will be received by "MC_FireMJEvent" and it will use the delegate pointer to trigger "MyRelayEvent", which can act on the event.

Note: The event handler is automatically created in a separate thread from the main routine/class. One thread cannot make changes to another thread, so it is necessary to use the delegate pointer to make the main thread aware that the event occured and to receive the information. Then the receiving subroutine, which is in the main thread, can make updates without creating an exception error.

Handling the events from Visual C++ with MFC

In your C++ MFC application, you should have a class which is derived from CCmdTarget (or from CWnd or CDialog which derive from CCmdTarget). This class will sink the events from MC's automation object. In the sample code below, this class is called "CMyClass", substitute your class's name for CMyClass. In the header file of the class, add the following import using the correct tlb path for your system. Also add the afxctl.h include file if you get warnings of undefined AfxConnectionAdvise and AfxConnectionUnadvise.

 #import "C:\\Program Files\\J River\\Media Center 12\\Media Center 12.tlb" no_namespace, named_guids
 #include "afxctl.h"

Then within the header file's class declaration for CMyClass, add this code:

  DECLARE_DISPATCH_MAP()
  DECLARE_INTERFACE_MAP()
  afx_msg void MJEvent(LPCTSTR strType, LPCTSTR strParam1, LPCTSTR strParam2);
  IMJAutomationPtr m_pMJ;
  DWORD m_SinkID;

Now in the cpp file for the class, add these lines which connect your handler function to the correct entry in the dispatch map:

  BEGIN_DISPATCH_MAP(CMyClass, CCmdTarget)
    DISP_FUNCTION_ID(CMyClass,"MJEvent",1,MJEvent,VT_EMPTY,VTS_BSTR VTS_BSTR VTS_BSTR)
  END_DISPATCH_MAP()

  BEGIN_INTERFACE_MAP(CMyClass, CCmdTarget)
    INTERFACE_PART(CMyClass, DIID_IMJAutomationEvents, Dispatch)
  END_INTERFACE_MAP()

Now add the following code to the constructor or wherever you do initialization:

  CoInitialize(NULL);
  EnableAutomation();
  HRESULT hr = m_pMJ.GetActiveObject (L"MediaJukebox Application");
  if (hr != S_OK)
    m_pMJ.CreateInstance(L"MediaJukebox Application");

  // Get a pointer to the sink IDispatch interface
  LPUNKNOWN pUnknownSink = GetIDispatch(FALSE);

  // Connect the event source (MJ automation) to the sink
  AfxConnectionAdvise(m_pMJ, DIID_IMJAutomationEvents, pUnknownSink, FALSE, &m_SinkID);

Add the function body which receives the events:

  // MJAutomationSink message handler
  void CMyClass::MJEvent(LPCTSTR strType, LPCTSTR strParam1, LPCTSTR strParam2)
  {
    // handle events here...
  }

And finally, add this code to the destructor or wherever you do final cleanup. The release for m_pMJ has to be called prior to CoUninitialize.

  LPUNKNOWN pUnknownSink = GetIDispatch(FALSE);
  AfxConnectionUnadvise(m_pMJ, DIID_IMJAutomationEvents, pUnknownSink, FALSE, m_SinkID);
  m_pMJ.Release();
  CoUninitialize();

Handling the Events from Visual C++ with ATL

If you have a conventional Interface plugin that was generated using the ATL DLL and ATL composite controls, you can also sink MediaCenter's events. Simply implement the IMJAutomationEvents (perhaps using class view->Implement Interface) using the IDispEventImpl template. The wizard will default to IDispatch, but you will need to use IDispEventImpl and the SINK_MAP functions to handle events correctly.

Ensure that the type library is imported as for the MFC version above. Set your SINK_MAP as follows:

BEGIN_SINK_MAP(CEQdbCtrl)
  SINK_ENTRY_EX(1, DIID_IMJAutomationEvents, 1, MJEvent)
END_SINK_MAP()

and then implement the MJEvent handler function

STDMETHOD_(void, MJEvent)(LPCTSTR strType, LPCTSTR strParam1, LPCTSTR strParam2);

Also, you need to advise the sink after attaching to the passed IDispatch* in your Init function.

HRESULT hr;
hr = DispEventAdvise(m_pMJ, &DIID_IMJAutomationEvents);
if(hr == S_OK) {
  // Successfully advised.
} else {
  // Did not advise correctly.
}

Here's the (somewhat) tricky part. Using the CComComposite class means that AtlAdviseSinkMap is called during the window constructor, and it will cause an ATLASSERT failure during debug builds. This produces the "Abort" "Retry" "Ignore" message box stating there's been an assertion failure in atlcom.h. Click ignore. Once you move to release builds, it will compile to nothing and will not cause you any trouble.